Product Description
Ground connection
The ground connection of the read/write head is positioned on the right-hand side when
viewed from the front, if the cable outlet is facing downward. The ground conductor is screwed
to the housing with a crimp connector. In order to guarantee safe grounding, mount the ser-
rated washer between the crimp connectors and the housing.
The screw connection, which is marked with the symbol or depending on the device
type, is used to connect the functional earth.
Use a ground conductor lead with a cross-section of at least 4 mm
2
.
Tighten the retaining bolt to a tightening torque of 1.6 Nm ± 0.4 Nm.
3.7 Scope of Delivery
Read/write head
Quick start guide
3.8 Accessories
3.8.1 IDENTControl
The IUH-F190-V1-* read/write head can be connected to Pepperl+Fuchs IDENTControl control
interfaces.
4 Data input/output B, RS-485, -7 V ... +12 V
5 Data output 0 3.3 V
DC
1 Housing
2 Serrated lock washer
3 Crimp connector
4 Lock screw
1 2 43