User Manual
Table Of Contents
- 1 Introduction
- 2 Certificates and approvals
- 3 Product Description
- 3.1 RFID Frequency Bands
- 3.2 UHF general
- 3.3 Countries of Use
- 3.3.1 European Union
- 3.3.2 Argentina
- 3.3.3 Australia
- 3.3.4 Brazil
- 3.3.5 Canada
- 3.3.6 China
- 3.3.7 Hong Kong
- 3.3.8 India
- 3.3.9 Japan
- 3.3.10 Colombia
- 3.3.11 Malaysia
- 3.3.12 Morocco
- 3.3.13 Mexico
- 3.3.14 New Zealand
- 3.3.15 Russia
- 3.3.16 Singapore
- 3.3.17 South Korea
- 3.3.18 Thailand
- 3.3.19 United States of America
- 3.3.20 Vietnam
- 3.4 General Functions and Features
- 3.5 Indicators and Operating Elements
- 3.6 Connection
- 3.7 Scope of Delivery
- 3.8 Accessories
- 4 Installation
- 5 Commissioning
- 6 Operation
- 7 Service and Maintenance
- 8 Troubleshooting
- 9 Appendix
2022-11
34
IUH-F192-V1-*
Commissioning
Reading Tags
Enhanced Read Read-Only Code
Send the enhanced read read-only code command to the read/write head. The "RF ON" LED
on the read/write head lights up blue.
Move a tag into the read/write head's detection range. When the tag has been detected and the
read-only code has been read out, the "READ / WRITE" LED on the read/write head lights up
yellow. The read-only code is displayed in the terminal program.
Describing Tags
Single Write Special Read-Only Code
Send the single write special read-only code command to the read/write head while a tag is in
the detection range. See "Single Write Special Read-Only Code SP" on page 39 and see chap-
ter 3.2.4.
Serial Ethernet PROFIBUS/PROFINET
Command: EF1 .00.04.1D.03 .1D.03
Confirmation: - .00.06.1D.03.FF.0B .1D.03.FF.0B
Response: .35.31 .00.06.1D.03.05.0C .1D.03.05.0C
Table 5.1 Enhanced read read-only code, no tag in the detection range
Serial Ethernet PROFIBUS/PROFINET
Response: .30.31.00.0E.30.
00.30.14.F7.33.7
C.00.1F.00.00.00
.00.01.00.08.E2.
00.60.03.14.42.D
6.D1
.00.20.1D.03.00.0D.00.0E.
30.00.30.14.F7.33.7C.00.1
F.00.00.00.00.01.00.08.E2
.00.60.03.14.42.D6.D1
.1D.03.00.0D.00.0E.30.00.
30.14.F7.33.7C.00.1F.00.0
0.00.00.01.00.08.E2.00.60
.03.14.42.D6.D1
Table 5.2 Enhanced read read-only code, tag is entering the detection range
Serial Ethernet PROFIBUS/PROFINET
Command: SP1E.30.00.30.1
4.F7.33.7C.00.1F
.00.00.03.1C.6E
.00.14.0D.E3.00.00.30.00.
30.14.F7.33.7C.00.1F.00.0
0.03.1C.6E
.0D.E3.00.00.30.00.30.14.
F7.33.7C.00.1F.00.00.03.1
C.6E
Confirmation: - .00.06.0D.E3.FF.2D .0D.E3.FF.2D
Response: .30.31.00.0E.30.
00.30.14.F7.33.7
C.00.1F.00.00.03
.1C.6E
.46.31.30.30.30.3
1
.00.16.0D.03.00.2E.00.0E.
30.00.30.14.F7.33.7C.00.1
F.00.00.03.1C.6E
.00.0A.0D.03.0F.2F.30.30.
30.31
0D.03.00.2E.00.0E.30.00.
30.14.F7.33.7C.00.1F.00.0
0.03.1C.6E
.0D.03.0F.2F.30.30.30.31