IUH-F192-V1-*
Commissioning
Reading Tags
Enhanced Read Read-Only Code
Send the enhanced read read-only code command to the read/write head. The "RF ON" LED
on the read/write head lights up blue.
Move a tag into the read/write head's detection range. When the tag has been detected and the
read-only code has been read out, the "READ / WRITE" LED on the read/write head lights up
yellow. The read-only code is displayed in the terminal program.
Describing Tags
Single Write Special Read-Only Code
Send the single write special read-only code command to the read/write head while a tag is in
the detection range. See "Single Write Special Read-Only Code SP" on page 39 and see chap-
ter 3.2.4.
Serial Ethernet PROFIBUS/PROFINET
Command: EF1 .00.04.1D.03 .1D.03
Confirmation: - .00.06.1D.03.FF.0B .1D.03.FF.0B
Response: .35.31 .00.06.1D.03.05.0C .1D.03.05.0C
Table 5.1 Enhanced read read-only code, no tag in the detection range
Serial Ethernet PROFIBUS/PROFINET
Response: .30.31.00.0E.30.
00.30.14.F7.33.7
C.00.1F.00.00.00
.00.01.00.08.E2.
00.60.03.14.42.D
6.D1
.00.20.1D.03.00.0D.00.0E.
30.00.30.14.F7.33.7C.00.1
F.00.00.00.00.01.00.08.E2
.00.60.03.14.42.D6.D1
.1D.03.00.0D.00.0E.30.00.
30.14.F7.33.7C.00.1F.00.0
0.00.00.01.00.08.E2.00.60
.03.14.42.D6.D1
Table 5.2 Enhanced read read-only code, tag is entering the detection range
Serial Ethernet PROFIBUS/PROFINET
Command: SP1E.30.00.30.1
4.F7.33.7C.00.1F
.00.00.03.1C.6E
.00.14.0D.E3.00.00.30.00.
30.14.F7.33.7C.00.1F.00.0
0.03.1C.6E
.0D.E3.00.00.30.00.30.14.
F7.33.7C.00.1F.00.00.03.1
C.6E
Confirmation: - .00.06.0D.E3.FF.2D .0D.E3.FF.2D
Response: .30.31.00.0E.30.
00.30.14.F7.33.7
C.00.1F.00.00.03
.1C.6E
.46.31.30.30.30.3
1
.00.16.0D.03.00.2E.00.0E.
30.00.30.14.F7.33.7C.00.1
F.00.00.03.1C.6E
.00.0A.0D.03.0F.2F.30.30.
30.31
0D.03.00.2E.00.0E.30.00.
30.14.F7.33.7C.00.1F.00.0
0.03.1C.6E
.0D.03.0F.2F.30.30.30.31