User Manual

Table Of Contents
IUH-F192-V1-*
Operation
2022-11
47
6.6.2 Read and Write Parameters
With the read parameter (RP) and write parameter (WP) configuration commands, you can
read/write the following parameters:
The parameters are saved in the read/write head as nonvolatile.
Abbreviation Page
Parameter
IUH-F192-V1-FR*
AP See "Antenna Polarization AP" on page 48 Readable/writeable
CD See "CD Transmission Channels" on page 49 Readable/writeable
for RC = 1, 4, 5, 6, 8
Readable for RC = 2,
3, 7, 9, 10, 11, 12, 13,
14
E5 See "Number of Unsuccessful Attempts until Status 5
"Enhanced Status 5" E5" on page 49
Readable/writeable
FL See "Read Out Filter Mask "Filter List" FL" on page 49 Readable
IF See "Output Additional Information, "Information" IF"
on page 50
Readable/writeable
MB See "Memory Module for Tag Accesses to the "Mem-
ory Bank" MB" on page 50
Readable/writeable
MD See "Retrieve Additional Information MD" on page 51 Readable
MF See "Measurement of Reflected Transmitting Power
"Measure Reflection" MF" on page 51
Readable
NC See "Number of Channels NC" on page 51 Readable/writeable
for RC = 2, 3, 7, 9, 10,
11, 12, 13, 14
Readable for RC = 1,
4, 5, 6, 8
NT See "Search Algorithm Cancellation Criteria "number
of tags to find" NT" on page 52
Readable/writeable
PT See "Transmission Power "Power Transmit" PT" on
page 52
Readable/writeable
QV See "Protocol Mode QV" on page 53 Readable/writeable
QW See "Q Value QW" on page 54 Readable/writeable
RC See "Country Identifier, "Region Code" RC" on page
55
Readable/writeable
1
1. Readable only for IUH-F192-V1-FR2-02
RD See "Reset to Default, RD" on page 55 Writeable
SM See "Transmission Pauses in "Sensing Mode" SM" on
page 56
Readable/writeable
TA See "Number of Attempts "Tries Allowed" TA" on page
57
Readable/writeable