CD Transmission Channels
Programmable frequency list frequency access method:
This parameter sets the number and sequence of transmission channels or reads out the num-
ber and sequence of transmission channels.
Frequency hopping spread spectrum frequency access method:
This parameter reads out the number and sequence of transmission channels for the fre-
quency hopping spread spectrum.
Example:
WP1UCD.00.04.07.0A.04.0D defines the sequence 7, 10, 4, and 13 as the permitted transmis-
sion channels
WP1UCD.00.01.0A allows the read/write head to use only transmission channel 10
RP1UCD.00.00 reads out the sequence of permitted transmission channels
Number of Unsuccessful Attempts until Status 5 "Enhanced Status 5" E5
This parameter sets the number of unsuccessful read/write attempts until a status 5 is output for
an enhanced command, or outputs the number.
Status 0 and status A depend on this parameter, and are output immediately.
Example:
WP1UE5.00.01.05 sets the number to 5 unsuccessful read/write attempts until a status 5 is out-
put
RP1UE5.00.00 outputs the number
If the number of read/write attempts is reduced:
Faster response time in enhanced mode.
Status 5 messages in the event of unstable tag reading.
Read Out Filter Mask "Filter List" FL
Parameter FL contains the current configuration of the filter masks as set during execution of
command FI. The output format corresponds to the data input format of command FI without
the filter number. The parameter can only be read, but not set.
Example:
RP1UFL.00.01.02 outputs the current configuration of filter 2
ParamTyp: CD
Default: Depends on the country identifier set, see chapter 3.3.
Value range: Depends on the country identifier set, see chapter 3.3.
Tip
If you have parameterized several transmission channels with the parameter CD, the read/write
head executes each write or read command on all defined transmission channels sequentially
according to the defined sequence. If several additional transmission power values are
parameterized (), all set transmission powers are executed on each transmission channel for
each read or write command. See chapter 6.2.
ParamTyp: E5
Default: E5 = 5
Value range: 0 ... 252
ParamTyp: FL
Value range: 0 ... 2