User Manual

Table Of Contents
IUH-F192-V1-*
Operation
2022-11
55
Example:
WP1UQW.00.01.04 sets the Q value to 4. The read/write head therefore works with 2
4
= 16
time slots.
RP1UQW.00.00 outputs the set Q value.
Country Identifier, "Region Code" RC
Parameter RC sets a country identifier or reads out the current country identifier.
The country identifier consists of two bytes:
1. Byte = 00
You can change the country identifier
1. Byte = 80
You cannot change the country identifier
The country identifier can be set to write-protected by the manufacturer only. The first byte is
then set to 80. The second byte defines the country identifier. For all the available country iden-
tifiers, see chapter 5.2, and for the corresponding technical details, see chapter 3.3.
Example:
WP1URC.00.02.00.03 sets the country identifier to China.
RP1URC.00.00 reads out the country identifier set.
The serial response .30.31.00.01 indicates the country identifier for Europe, which you can
modify.
The serial response .30.31.80.02 indicates the country identifier for the IUH-F192-V1-FR2-02,
which is set by the manufacturer. You cannot change this country identifier.
Reset to Default, RD
This parameter returns all settings of the read/write head to the default configuration.
Example:
WP1URD.00.00
ParamTyp: RC
Default setting: .00.00 (green LED flashes)
Value range: See chapter 5.2
Note
Once you have set the country identifier, the read/write head automatically resets all other
parameters to their respective default values. When programming or configuring parameters
manually, always set the correct country identifier before changing any other parameters.
Note
The country identifier remains unchanged when the default status is restored.
Note
The IUH-F192-V1-FR2-02 is supplied ex-works with the country identifier "02" for the USA,
Canada, and Mexico. Due to legal regulations, you cannot change this country identifier in the
IUH-F192-V1-FR2-02.
ParamTyp: RD