User Manual

Table Of Contents
2022-11
56
IUH-F192-V1-*
Operation
Default Value Parameters
Transmission Pauses in "Sensing Mode" SM
The parameter SM defines a pause time in milliseconds. This pause time is executed once all
runs are complete.
This parameter is especially useful for continuous operation with "enhanced" commands (see
chapter 6.4). If you specify transmission pauses, you can operate the read/write head at higher
ambient temperatures.
Example:
WP1USM.00.02.27.10 sets the pause time to 10,000 ms = 10 seconds.
RP1USM.00.00 reads out the pause time.
Abbre-
viation Parameter Default value
AP Antenna Polarization AP Combined mode (C)
CD Transmission Channels Depending on the country-specific set-
tings,
E5 Number of unsuccessful attempts up to
Status 5
5
FL Read Out Filter Mask No filter set (0)
IF Output Additional Information Off (0)
MB Memory Bank User Memory (3)
MD Retrieve Additional Information MD Not applicable
MF Measurement of Reflected Transmission
Power
Not applicable
NC Number of Channels Depending on the country-specific set-
tings,
NT Search Algorithm Cancellation Criteria Off (255)
PT Power Transmit Depending on the country-specific set-
tings,
QV Protocol Mode QV Multiframe Protocol (M)
QW Q Value 2
RC Country Identifier, "Region Code" Not applicable
RD Reset to Default Not applicable
SM Transmission Pauses in "Sensing Mode" 0
TA Number of Attempts, "Tries Allowed" TA 2
ParamTyp: SM
Default:
SM = 100 ms
1
SM = 0 ms
2
1. For all FR1 read/write heads
2. For all FR2 read/write heads
Value range:
100 ms ... 65,535 ms, 2 bytes
3
0 ms ... 65,535 ms, 2 bytes
4
3. For all FR1 read/write heads
4. For all FR2 read/write heads