Cut Sheet

Ultrasonic 30 mm Cylindrical
Ultrasonic Sensors
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Germany: +49 621 776 0
fa-info@de.pepperl-fuchs.com
Pepperl+Fuchs Group
www.pepperl-fuchs.com
Subject to modifications without notice Copyright Pepperl+Fuchs
320
Note:
Wiring diagrams show
quick disconnect pin numbers.
Quick Disconnect
V95 Type
Wiring Diagrams
30 mm Diameter
AC Switch Point
Output
500 mm (20") and 2 m (6.5') models
120 VAC powered
330° visibility of LEDs
Fingertip range adjustability (simply
turn the knob to adjust the range)
700 mA maximum load current
Specifications
AC Switch Point
SUPPLY VOLTAGE
90-140 VAC
OUTPUT (THYRISTOR)
LOAD CURRENT 700 mA
LEAKAGE CURRENT 0.6 mA
VOLTAGE DROP 1.5 VAC
SHORT CIRCUIT AND
OVERLOAD PROTECTED
No
LED(S)
Yes (2)
CURRENT CONSUMPTION
75 mA
REPEATABILITY
UB500
5 mm
UB2000
20 mm
HYSTERESIS
UB500
15 mm
UB2000
30 mm
STANDARDS
EN 60947-5-2
PROTECTION IEC
IP65
STANDARD TARGET
100 mm x 100 mm flat plate
TEMPERATURE
RANGE
WORKING -13 °F to +158 °F (-25 °C to 70 °C)
STORAGE -40 °F to +185°F (-40 °C to 85 °C)
HOUSING MATERIAL
Nickel-plated brass
TRANSDUCER
Epoxy resin/silica composite; foam
polyurethane, surround PBT
TEMPERATURE DRIFT
See page 283
APPROVALS
ELECTRICAL CONNECTION
5-pin Mini
(V95)
*Frequency for multiplex mode is divided by the number of sensors.
AC Switch Point Models
Model Number Sensing Range Unusable Area Output Transducer Freq. Response Time Switching Freq.
UB500-30GM65-WS3-BHMS5
70-500 mm 0-70 mm Thyristor, 1 NO 400 kHz 45 ms 15 Hz
UB2000-30GM65-WS3-BHMS5
200 mm-2 m 0-200 mm Thyristor, 1 NO 175 kHz 90 ms 3.5 Hz
AC Switch Point Output
See pages
865-872 for
accessories
See pages
803-854 for
cordsets
The rugged housing allows these sensors to be used in
demanding environments. A potentiometer sets the single
switch point output.
Stocked item
Typical delivery 4 weeks or less
Consult factory for all other models

Summary of content (2 pages)