User manual

EWL330/EWL350
V. 01 25/07/2013 4 ©Velleman nv
Only use the device for its intended purpose. All other uses may lead to short circuits, burns, electroshocks,
lamp explosion, crash, etc. Using the device in an unauthorised way will void the warranty.
Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the
dealer will not accept responsibility for any ensuing defects or problems.
Use the original packaging if the device is to be transported.
Keep this manual for future reference.
4. Features
die-cast aluminium housing with tempered glass
ribbed for maximum heat dissipation
extendable tripod (75-150 cm)
suited for outdoor use (IP65).
5. Overview
Refer to the illustrations on page 2 of this manual.
LED
3
hinge
5
pole connector
protective glass
4
upper pole
6
stand
6. Installation
1. Place the device on a flat and sturdy surface.
2. To adjust the height, hold the upper pole [4] and loosen the pole connector [5]. Slide the upper pole to the
desired height and tighten the pole connector.
3. To point the lamp in the desired direction: loosen the hinges [3] using a spanner. Tilt the lamp in the
desired angle and tighten the hinges.
4. Connect the power cord to a suitable, earthed mains outlet.
7. Cleaning and Maintenance
All screws should be tight and free of corrosion.
Mechanically moving parts must not show any signs of wear and tear.
The electric power supply cables must not show any damage. Have a qualified technician maintain the
device.
If the protective glass [2] is damaged, disconnect the lamp immediately from the mains. Have it repaired
immediately by a qualified technician. Do not use the lamp with a cracked or broken protective glass.
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
There are no user-serviceable parts.
Contact your dealer for spare parts if necessary.
8. Technical Specifications
EWL330
EWL350
power supply
230 VAC
230 VAC
max. power
33 W
54 W
LED
30 W COB Epistar
50 W COB Epistar
body colour
grey
grey
colour temperature
6500 K
6500 K
beam angle
120°
120°
luminous flux
1800 lm
3000 lm
adjustable height (top of the spot)
95-170 cm
100-175 cm
cable
H05RN-F 3G0.75, 3 m
H05RN-F 3G0.75, 3 m
weight
4280 g
5370 g