3b. Floor drain installation— Affix the RED ¼’ drain tubing above the floor
drain such that the drain tubing is at least 3” above the high point of any
standing water. Do not allow the opening of the RED ¼’ drain tubing to come
in contact with the ground or any standing water.
4. Water line out to point of use – Locate BLUE ⅜” tubing and connect to
the user supplied point of use using a user supplied fitting. Do not allow the
opening of the BLUE ⅜” tubing to come in contact with the ground or any
standing water.
5a. UNDERSINK INSTALLATION: Pressurize the —HydroGardener® - Make sure
unit exterior and fittings are dry. Water should flow normally from your sink’s cold and
hot faucet. Double check to make sure all valves are in the CLOSED position, except
for the main angle-stop valves, which should be OPEN. SLOWLY open the inline ball
valve at the EZ adapter. You should hear water flowing through the system. Check for
leaks at all fittings. Allow 5-15 minutes for system pressure to build. A thin steady (or
pulsing in Pro model) trickle of water should be present after 2-20 minutes from the
BLUE ⅜” tubing or your point of use. Some blackening of the water may present due
to loose carbon being flushed out. Allow 10 gallons of water to be produced to flush
the system and make it ready for use. Membrane contains a mild preservative.
System must be flushed prior to use.
5b. GARDEN HOSE INSTALLATION: Pressurize the Tap Master Artesian—
HydroGardener® - Make sure unit is dry. SLOWLY open the garden hose water
valve. SLOWLY open the inline ball valve at the EZ adapter. You should hear water
flowing through the system. Check for leaks at all fittings. Allow 5-15 minutes for
system pressure to build. A thin steady (or pulsing in Pro model) trickle of water
should be present after 2-20 minutes from the BLUE ⅜” tubing or your point of use.
Some blackening of the water may present due to loose carbon being flushed out.
Allow 10 gallons of water to be produced to flush the system and make it ready for
use. Membrane contains a mild preservative. System must be flushed prior to use.
6. IMPORTANT— the HydroGardener® is meant for a wide variety of plant
types. Test the product water pH and TDS and adjust to your plant’s needs.
Once the system flush is complete (step 5) your product water TDS should be
equal to >98% of tap plus 15-30 ppm of added cal/mag. pH will vary between
7-8. You may need to add acid down drops depending on your plant
type.