WARNING:
Prior to performing any assembly and/or adjustment procedures, make sure the Power Cord
of the Miter Saw is unplugged from its electrical outlet. Make sure the unit has compietety
cooled, and wear heavy-duty work gloves.
square. If not:
1. Use an open-end wrench to loosen the hex lock nut and then turn the hex stop bolt at the
back left side of the table.
2. Turn the bolt clockwise and the 45 degrees point moves left, opening the angle. Turning it
counter-clockwise moves the 45 degrees stop to the right, closing the angle.
3. When you have established the 45 degrees stop correctly, tighten the lock nut down to hold
the setting.
4. Make sure that the needle points to 45 degrees on the scale. If not, loosen the screws and
adjust the needle.
1. When replacing the saw blade, make sure the new saw blade has a diameter of 7-1/4", an
RPM rating of at least 6000, an arbor hole of 5/8" diameter.
2.
When mounting the new saw blade, the direction
arrows on the blade correspond with the arrow
on
the upper guard.
A. Upper blade guard
B. Lower blade guard
C. Saw teeth pointing down
(See Figure 1)
3. Put the saw in the upper position.
(See Figure 2)
Replacing Saw Blade
9
Bevel Scale
carpenter square
FIG.1
B
C
A
FIG.2