Vertical Installation Instructions

Laminate Flooring on Wall Installation Instructions
Vertical Wainscot Style
Although originally designed as a durable oor covering, many consumers have started using Pergo laminate ooring on walls to give their rooms more
character and to create a feature or accent wall.
Laminate can be utilized as a decorative covering over an existing clean, dry, secure and vertical wall that meets building codes. The wall substrate should
be primed or painted drywall (gypsum board) only. Do not install directly over wallpaper or paneling. Laminate is not intended to be used on ceilings,
countertops or as any type of structural material.
The installation wall should only run vertical to the oor. Sloping walls and surfaces that are parallel to the oor, such as ceilings or sots, should not be
selected. Limit installations to a maximum of 40 feet in length and a maximum of 1 plank length in height.
Laminate is suitable for an accent wall when used in climate controlled (35-65% RH and 60-85° F) indoor installations only. Acclimate unopened product
lying at in the room where it is to be installed for at least 48 hours. Mix planks from dierent cartons as you install to maximize the natural appearance.
Check wall for moisture, visible water stains or leaking windows. Do not install laminate over a wall with known moisture damage. Do not install in areas
near water sources such as a backsplash over a sink or bathtub. Acceptable job site conditions, including relative humidity and wall moisture conditions,
must be maintained throughout the life of the laminate application.
Check wall for atness within 3/16" over 10 feet. Correct any unevenness before installing to allow the laminate planks to lie at without rocking.
The following requirements are not intended to supersede federal, state or local building codes, but as with many other interior nish products, may re-
quire modifying existing structural components for successful installation. Owner assumes responsibility for compliance with all building codes, including
maintaining the required distance from heat sources such as replaces.
WARNING: For a safe and secure installation, this product MUST be installed in accordance with these installation instructions.
Tools Required for Installation:
• Caulk gun
• Utility knife
• Stud nder (electronic)
• Carpenters level or laser level
• Chalk line
• 18 gauge brad nail gun (electric or air)
• Tape measure
• Pencil
• Safety glasses
• Dust mask
• Gloves
Materials Required for Installation:
• 1-1/2" – 1-3/4" brad nails
• 100% silicone adhesive caulk (clear)
Other Tools and Materials:
• Hammer
• Uniclic
®
appropriate tapping block
• Pull bar
• Saw for cutting laminate planks
• Pry bar (for removing existing base or trim)
Chair rail, wall base and quarter round moldings (to
frame out accent wall)

Summary of content (5 pages)