Use and Care Manual

PERLICK RESIDENTIAL COLUMN REFRIGERATION USE & CARE GUIDE
16 | perlick.com/residential
INSTALLING FILTERS
CARBON AIR FILTERS
Carbonairltersshouldbeplacedintheholderinthe
perforatedpanellocatedinthetop-rearofthecabinet(A).
NOTE: When installing carbon air lter in wine units, the top
rack will need to be removed to access the perforated panel.
1.Removethelterfromtheplascbagbeforeinstallinginto
theunit.Takecarenottoopenorpuncturethetyvekbaginthe
casing.
2.Pullrmlytolowerthecarbonairlterpanel.
3.Placethecarbonairlterintotheholderdirectlyontothe
panelandclosepanel-pushrmlytoengageclosureclips.
4.Itisrecommendedtoreplacethecarbonairlterevery3-6
months.
B
ETHYLENE FILTERS
Ethyleneltersshouldbeplacedintheholderintopofthep-
outproducebin(B).
1.Removethelterfromtheplascbagbeforeinstallinginto
theunit.Takecarenottoopenorpuncturethetyvekbaginthe
casing.
2.Openthep-outbintoaccesslterhousinglocatedonthe
top of the bin.
3.Slidelterintohousingandclosep-outbin.
4.Itisrecommendedtoreplacetheethylenelterevery3
months.
Needtoorderreplacementlters?Contactyour
sellingdealerorvisitperlick.com/residenal to
ndaPerlickdealernearyou.