6.9 Replace Inverter (cont.)
STEP 10
Make sure the tube/wire access hole is fully sealed to prevent air leaks.
STEP 11
Install refrigeration module following instruction 6.6.
STEP 12
New harness 1015081 gets connected to spare black/wire lead set from cabinet.
Note: Inverter signal leads are connected to control board connection P4 for the frequency converter.
Figure 6-15.9. Seal Access Hole
Figure 6-15.10. Connect New Harness