Owner Manual

PERLICK RESIDENTIAL INSTALLATION MANUAL
6
perlick.com
LED Functions
The following table describes LED Funtions
DIGITAL TEMPERATURE CONTROL
C-Series Models
Figure 2. nEW 961 Digital Temperature Controller
To Change Setpoint Temperature
1. Press . “SP will be displayed. Press again to display
current setpoint temperature.
2. Press and to modify it and or to save the
change.
On/O
To turn the unit o, press and hold for at least 5 seconds.
“OF” will be displayed. To turn the unit on again, press and hold
for at least 5 seconds.
Perlick C-Series units come standard with digital control.
Programming Button Denitions:
Defrost LED
Permanently on: defrost active
Flashing: manual defrost active
O: otherwise
Alarm LED
Permanently on: alarm active
Flashing: alarm acknowledged
O: otherwise
Evaporator LED
Permanently on: fans active
O: otherwise
Compressor LED
Permanently on: compressor active
Flashing: a delay, a protection or a
locked start-up
O: otherwise
Aux LED
Permanently on: Aux output
active
O: otherwise
°C LED
Permanently on: display the
temperature
O: otherwise
STAND-BY (ESC)
Press and release
Returns to the previous
menu level
Conrms parameter value
Press for at least 5 sec.
Activates the Standby
function (o) (When
outside the menus)
SET (ENTER)
Press and release
Opens Machine Status menu
and displays alarms (if active)
Press for at least 5 sec.
Opens Programming menu
Conrm commands
UP
Press and release
Scroll menu items
Increases values
Press for at least 5 sec.
Activates the Manual
Defrost function
DOWN
Press and release
Scroll menu items
Decreases values
Press for at least 5 sec.
Function can be congured
by the user
NOTE: Dependent on the model and conguration, the controllers
have been programmed to only allow a temperature adjustment
within a specied range. See the chart below for the specied range
allowed for your unit.
NOTE: When switched on, the device performs a Lamp Test; the
display and LEDs will ash for several seconds to check that they all
function correctly.
C-Series Models
Model Temp Range
HC24R 33° - 42° F
HA24BB 33° - 48° F
HA24WB 45° - 65° F
DIAL TEMPERATURE CONTROL
ADA-Compliant Models
(Excludes ADA Freezer - HA24F models use digital controller found
on page 5)
C
O
O
L
E
R
OFF
1
2
3
4
5
6
COLD
Figure 3. Dial Temperature Controller
Use a straight slot screwdriver to adjust the dial temperature
control. The control is located at the top rear panel of the
cabinet. Approximate temperature ranges are as follows:
ADA-Compliant Series
Model Temp Range
HA24RB 33° - 42° F
HA24BB 35° - 48° F
HA24WB 45° - 65° F