Use & Care Guide

perlick customer service (800)558-5592 | 5
PERLICK RESIDENTIAL UNDERCOUNTER USE & CARE GUIDE
NOTE: Dependent on the model and conguration, the controllers have
been programmed to only allow a lower compartment temperature
adjustment range as specied within the chart below. The upper
compartment range is not limited, but should always be kept within
the specied range shown in the table for the upper compartment. See
the chart below for the specied range allowed for your unit.
Temperature Scale
To change F to C, press and hold the down arrow for 3 seconds.
To Start A Manual Defrost (HP24Z Models Only)
Press and hold the DEFROST button (melting snowake) for 3-5
seconds. Melting snowake will illuminate.
15”, 24” Single Zone, 24” Shallow Depth, and ADA Controls
To Set Target Temperature
Press and release the SET button. Display will show the current
temperature setpoint.
To Change Setpoint Temperature
1. Press and hold the SET button until the display shows the
current setpoint temperature with the “F” ashing.
2. Use the UP and DOWN arrow button to scroll to the desired
temperature.
To Start A Manual Defrost (Freezer Models Only)
Press the DEFROST button (melting snowake).
To See Maximum Stored Temperature
Press the UP arrow button to see the maximum stored tempera-
ture. To reset the maximum stored temperature, while displayed,
press and hold the SET button until ‘rst’ ashes in the display.
To See Minimum Stored Temperature
Press the DOWN arrow button to see the minimum stored tem-
perature. To reset the minimum stored temperature, while dis-
played, press and hold the SET button until ‘rst’ ashes in the
display.
On/O
Press the ON/OFF button to turn the unit on or o.
NOTE: Dependent on the model and conguration, the controllers
have been programmed to only allow a temperature adjustment
within a specied range. See the chart to right for the specied range
allowed for your unit.
Signature Series – HP15 Models
Model Min Temp Set Max Temp Set
HP15R 33° F 42° F
HP15B 33° F 48° F
HP15W 45° F 65° F
HP15T 33° F 42° F
Signature Series – HP24 Models
Model Min Temp Set Max Temp Set
HP24R 33° F 42° F
HP24F -10° F 10° F
HP24B 33° F 48° F
HP24W 45° F 65° F
HP24T 33° F 42° F
Signature Series Shallow Depth
Model Min Temp Set Max Temp Set
HH24RS 33° 42°
HH24BS 33° 48°
HH24WS 45° 65°
C-Series Models
Model Min Temp Set Max Temp Set
HC24RB 33° 42°
HC24BB 33° 48°
HC24WB 45° 65°
ADA-Compliant Series
Model Min Temp Set Max Temp Set
HA24FB -10° 10
HA24RB 33° 42°
HA24BB 33° 48°
HA24WB 45° 65°
LED Mode Function
ON Compressor is on
Flashing
Anti-short cycle
delay is on
ON Defrost is on
ON Alarm is on
Flashing
You are in the process of
programming the unit
LED Functions
The following table describes LED functions.
Signature Series – Dual-Zone Units
Model Range (F)
HP24Z Upper 33° - 42°F / Lower -10° - 10°F
HP24C Upper 45° - 65°F / Lower 33° - 42°F
HP24D Upper 51° - 65°F / Lower 45° - 55°F
Audible alarm will sound if the door is left ajar for longer than one
minute. Fully closing the door will clear the alarm condition, pro-
longed time spent with the door open can damage the equipment.