C-Series Operation & Installation Manual

20
Operation & Installation Manual
C-Series (HC24 models)
CAUTION
Do not use abrasive cleaners or cloths on any of the interior or exterior surfaces or removable parts.
Cleaning the Condenser
The condenser should be cleaned every three (3) months. The condenser is located behind the toe plate (Figure 6, page 10). Remove the
toe plate and use a soft bristle brush and vacuum to remove the dust and lint. Avoid damaging or crushing the condenser ns or tubing.
Upon completion, reinstall the toe-plate.
CAUTION
Failure to clean the condenser could result in temperature loss or mechanical failure. Clean this area every three months.
TROUBLESHOOTING
BEFORE CALLING FOR SERVICE:
If the unit appears to be malfunctioning, read through NORMAL OPERATION rst. If the problem persists, check the TROUBLESHOOTING
GUIDE. Locate the problem in the guide and refer to the cause and its remedy before calling for service. The problem could be
something which can be solved without a service call.
DANGER
NEVER ATTEMPT TO REPAIR OR PERFORM MAINTENANCE ON THE UNIT UNTIL THE MAIN ELECTRICAL POWER HAS BEEN
DISCONNECTED!
Problem: No interior light
Is the bulb loose?
Is the bulb burnt out?
Problem: Light stays on when door is closed
Manual ON/OFF light switch is turned ON
Is the door switch making contact with the door?
Problem: Noise during operation
Certain sounds are normal. Soft sounds from the compressor, fan motor and valves will be heard
Problem: The refrigerated cabinet isn’t running
Is there electrical power to the unit?
Is your home circuit breaker or fuse on?
Is control turned o?
Problem: The refrigerated compartment is warmer than usual
Is your control set properly?
Is the light staying on?
Is your condenser area clean and free of obstructions?
Has the door been open for a long time or more frequent door openings occured?
Are the internal louvers and fan guard openings obstructed?
Has warm product been placed in the cabinet?