C-Series Operation & Installation Manual

8
Operation & Installation Manual
C-Series (HC24 models)
INSTALLATION
CAUTION
Finished ooring should be protected with the appropriate
material to avoid damage from moving the unit.
If unit has been laid on its back or sides, place unit upright and
allow minimum of 24 hours before connecting power.
1. Plug the unit into the 15 amp grounded outlet located in the
installation opening. With power applied to the unit, check
that the lighting and cooling function operate properly, then
turn o power to the wall outlet at the circuit breaker.
WARNING
Shut o power to the wall outlet before installing unit into the
opening.
2. Check that the following are level and square:
front face and interior opening
installation opening and oor surface
countertop bottom front edge
IMPORTANT NOTE: The oor under the unit must be at the same
level as the surrounding nished oor.
3. If all surfaces are level, refer to Figure 6 (right) and perform
the following:
a. Measure from the oor to the bottom of the front edge of
the countertop.
b. Mesure the rear of the unit cabinet from oor to top of
cabinet, at back corners.
c. Adjust rear legs so B measurement equals A measurement.
Using an adjustable wrench of pliers, turn legs counter-
clockwise to raise the unit or clockwise to lower the unit.
IMPORTANT NOTE: Leveling legs should not extend more than
3/4” from bottom of the unit.
4. Slide cabinet into position. Make sure the rear levelling legs
slide under the anti-tip brackets. Push the unit into the open-
ing until the bottom front edge of the unit is ush with the
surrounding cabinetry, or until the rear legs are tight against
the anti-tip brackets.
5. Shim the front of the unit so the front face is ush with the
surrounding cabinetry. Adjust the front legs to support the
countertop at the shimmed height. Using an adjustable
wrench or pliers, turn the legs counterclockwise to raise the
unit or clockwise to lower the unit. Countertop should be
resting on top of the unit.
IMPORTANT NOTE: If countertop is not resting entirely on unit top,
shim the countertop to prevent damage to the countertop.
CAUTION
To prevent damage to the countertop and unit underneath, do
not place heavy objects on countertop directly above the unit.
6. Check interior door openings inside the cabinet to ensure
the cabinet is level. Reinstall all shelving and sliding drawers
squarely into slide brackets and proper slide bracket grooves.
When sliding shelving and drawers are installed properly
a click should be heard from both slide bracket retaining
clips and should slide smoothly in the tracks. When sliding
shelving or drawers are pulled out to full extension a stop is
activated to prevent additional pull-out.
CAUTION
Improper shelving or drawer installation may not actuate slide
stop mechanism.
Figure 6 - Leveling