Use & Care Guide
perlick customer service (800)558-5592 | 3
PERLICK RESIDENTIAL UNDERCOUNTER USE & CARE GUIDE
IMPORTANT!
Read and understand all information in this manual before attempting the installation. All plumbing 
and electrical work must be performed by a qualied technician and conform to all applicable state 
and local codes.
SAFETY
PLEASE READ all instructions completely before 
attempting to install or operate the unit. Take particular 
note of the DANGER, WARNING and CAUTION information 
in the manual. The information is important for the safe 
and ecient installation, operation and care of your Perlick 
unit.
DANGER
Indicates a hazard that WILL result 
in serious injury or death if 
precautions are not followed.
W ARNING
Indicates a hazard MAY cause 
serious injury or death if 
precautions are not followed.
CAUTION
Indicates a hazard where minor 
or moderate injury may occur if 
precautions are not followed.
NOTICE
Indicates that property damage 
may occur if warnings or 
instructions are not followed.
Refrigerant
DANGER
 Take caution when handling, 
moving and using the product to 
avoid damaging the refrigerant tubing or increasing 
the risk of a leak
WARNING
All service work shall be 
performed by factory authorized 
service personnel and all component parts shall be 
replaced with like components to minimize the risk of 
possible ignition due to incorrect parts or improper 
service.
CAUTION
 If service is necessary, repair work 
must be performed by a Perlick 
authorized servicer. Work done by unqualied 
individuals could potentially be dangerous and will 
void the warranty.
N OTICE
This product contains blown foam 
insulation using blowing agent 
R-611 (Methyl Formate). The foam in this product 
does not contain HFC’s, CFC’s, or HCFC’s.
All models covered in this user manual are manufactured 
using refrigerant R600a (Isobutane). R600a is a hydrocarbon. 
This refrigerant is ammable and is only allowed for use in 
appliances with fulll the requirements of UL/IEC 60335-1 
and UL/IEC 60335-2-24. (To cover potential risk originated 
from the use of ammable refrigerants). Consequently, 
R600a is only allowed to be used in refrigerating appliances 
with are designed for this refrigerant and fulll the above-
mentioned standard.
•  R600a is heavier than air. The concentration will always 
  be highest at the oor level.
•  The explosion limits are as follows:
  o  Lower Limit: 1.8% by volume
  o  Upper Limit: 8.4% by volume
  o  Ignition Temperature: 460°C
Prior To Installation
Carefully inspect cabinet for hidden damage. If damage is 
discovered, le your claim immediately with the transport 
company. Perlick is not responsible for damage in transit.
CAUTION
When moving the unit, be sure to 
protect nished ooring with ap-
propriate material to avoid damage from moving the 
unit.
CAUTION
Do not lift unit by drawer, shelving 
or door handles, as damage to the 
unit could occur if not moved as instructed.
WARNING
To prevent personal injury, a mini-
mum of two people are required to 
lift the unit. Larger units may require additional per-
sonnel.
Before moving the unit, secure the door shut with tape 
to prevent door from swinging open while being moved. 
Carefully move unit to installation site and place in front 
of opening.
CAUTION
If unit has been laid on its back or 
sides, place unit upright and allow 
minimum of 24 hours before connecting power.