Use and Care Guide

5
perlick.com
PERLICK RESIDENTIAL INSTALLATION MANUAL
To Set Target Temperature
Press and release the SET button. Display will show the current
temperature setpoint.
To Change Setpoint Temperature
1. Press and hold the SET button until the display shows the
current setpoint temperature with the “F” ashing.
2. Use the UP and DOWN arrow button to scroll to the desired
temperature.
Signature Series 15”, 24” Single-Zone and Sottile, and 48” ,
ADA Freezer Control Instructions
Dual-Zone Temperature Scale
To change F to C, press and hold the down arrow for 3 seconds.
To Start A Manual Defrost (HP24Z Models Only)
Press and hold the DEFROST button (melting snowake) for 3-5
seconds. Melting snowake will illuminate.
To Start A Manual Defrost (Freezer Models Only)
Press the DEFROST button (melting snowake)
To See Maximum Stored Temperature
Press the UP arrow button to see the maximum stored
temperature. To reset the maximum stored temperature, while
displayed, press and hold the SET button until ‘rst’ ashes in the
display.
To See Minimum Stored Temperature
Press the DOWN arrow button to see the minimum stored
temperature. To reset the minimum stored temperature, while
displayed, press and hold the SET button until ‘rst’ ashes in the
display.
On/O
Press the ON/OFF button to turn the unit on or o.
Signature Series – Dual-Zone Units
Model Range (F)
HP24Z Upper 30° - 42°F / Lower -10° - 10°F
HP24C Upper 45° - 65°F / Lower 30° - 42°F
HP24D Upper 51° - 65°F / Lower 45° - 60°F
Signature Series – HP15 Models
Model Min Temp Set Max Temp Set
HP15R 33° F 42° F
HP15B 33° F 48° F
HP15W 45° F 65° F
HP15T 33° F 42° F
Signature Series – HP24 Models
Model Min Temp Set Max Temp Set
HP24R 33° F 42° F
HP24F -10° F 10° F
HP24B 33° F 48° F
HP24W 45° F 65° F
HP24T 33° F 42° F
Signature Series – HP48 Models
Model Min Temp Set Max Temp Set
HP48WO 40° F 65° F
HP48WW 40° F 65° F
Signature Series Sottile
Model Min Temp Set Max Temp Set
HH24RS 33° 42°
HH24BS 33° 48°
HH24WS 45° 65°
ADA-Compliant Series
Model Min Temp Set Max Temp Set
HA24FB -10° 10
LED Functions
The following table describes LED functions
LED Mode Function
ON Compressor is on
Flashing Anti-short cycle
delay is on
ON Defrost is on
ON Alarm is on
Flashing You are in the process of
programming the unit
3. Use the UP or DOWN arrow key to scroll to the desired
temperature. The controller will memorize the new
temperature.
NOTE:Dependentonthemodelandconguration,thecontrollers
havebeenprogrammedtoonlyallowalowercompartment
temperatureadjustmentrangeasspeciedwithinthechartbelow.
Theuppercompartmentrangeisnotlimited,butshouldalways
bekeptwithinthespeciedrangeshowninthetablefortheupper
compartment.Seethechartbelowforthespeciedrangeallowed
foryourunit.
NOTE:Dependentonthemodelandconguration,thecontrollers
havebeenprogrammedtoonlyallowatemperatureadjustment
withinaspeciedrange.Seethechartbelowforthespeciedrange
allowedforyourunit.