Installation Guide

PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT
Perlick customer service (800)558-5592 | 9
Locate the beer faucet(s) and install onto the dispensing head
shanks. Tighten with supplied spanner wrench. Install black
handle(s) onto faucet(s).
12.
On the right rear sidewall there is a double column of screws.
Remove the left screw. Locate the safety chain and a #10 x
1/2” sheet metal screw from the parts bag. Insert the screw
through the closed end link of the chain and tighten in the
vacant screw hole. The chain can now be used to secure the
tank with “S” hook, preventing damage to the regulator.
CO2 tanks are shipped empty and must be lled prior to
use. Turn the adjusting knob on the regulator counter-
clockwise until the secondary gauge (top) reads zero.
Make sure that the valve at the bottom of the regulator
where the red hose is connected is in the o position as
shown. Watching the secondary pressure gauge, turn the
regulator adjusting knob clockwise until the pressure is at
15 psig. Adjustments can later be made based on ow rates.
IMPORTANT: All pressure adjustments MUST be made when
the shut-o valve is in the OFF position!
10.
11.
INSTALLATION