5 Customising Your SXV2
The Perreaux SXV2 gives you complete access to all cartridge-
loading parameters for each channel via the 12-way rear mounted
DIP switches.
Two DIP switches are required, as Perreaux engineers have
meticulously laid the internal circuitry out on the internal PCB
maintaining maximum isolation between channels. Each DIP
switch should be set to be a mirror of the other.
Cartridge load settings should be set up to directly correspond to
the cartridge manufacturers recommended loading figure. If you
don’t know the recommended loading of your cartridge, please
contact the cartridge manufacturer or your dealer for this
information.
It is recommended that you make adjustments to the settings
using a pen or other similar pointed object.
Impedance loading values are set using switches 1 through 5.
Capacitive loading values are set using switches 6 through 9.
Gain values are set using switches 10 and 11.
RIAA curve is selected using switch 12.
Caution!
NEVER change the DIP switch settings of your SXV2 whilst
it is turned on.
Note:
Each DIP switch should be set to be a mirror image of the
other channel.
Impedance
Loading
Table
Use this table to match the impedance loading characteristics of
your SXV2 to that recommended by your cartridge manufacturer,
where switch in UP position is OFF and switch in DOWN
position is ON. Consult your cartridge documentation for the
correct impedance figure.
R Load Dip Switch Setting
(
Ω
) 1 2 3 4 5
47000 UP UP UP UP UP
24000 DOWN UP UP UP UP
10000 UP DOWN UP UP UP
1000 UP UP DOWN UP UP
100 UP UP UP DOWN UP
10 UP UP UP UP DOWN