Specification Sheet

INSTALLATION INSTRUCTIONS
INSTALLATION CONTINUED
Step 2 Connect Dispenser
The electronic instant hot water appliance inlet connection is a 3/8” BSP male threaded
connector. The outlet connector is a 3/8” BSP male thread connector.
Check the connections type and size on the instant hot water Dispenser for the inlet and
outlet connections.
Screw on the inlet and outlet pipe the correct connectors and tighten with a wrench.
Connect the cold and hot Dispenser inlet hoses to the mains in the normal way. Fitting a
pressure reducing valve to the cold mains inlet if the mains pressure is above 5bar. Tighten
with a wrench and move to check the complete installation for leaks.
Step 3 Priming and Checking for Water Tightness
Before the electronic instant hot water appliance is plugged into the power socket it must
be tested for water ghtness and no leaks.
Open all water valves to allow water toow to the instant hot water Dispenser.
Turn the spring back instant hot water handle and hold to ll the electronic instant hot
water appliance this will take about 90 seconds.
When the electronic instant hot water appliance is full, water will ow from
the instant hot water Dispenser spout. Inially as air is purged the out let
may spit or spluer. To remove air from the system connue to operate the lever for 1-2
gallons or more if needed. Turn the instant hot water handle o and check all connecons
for water ghtness and leaks.
Any leaking joint must be ghtened to ensure no water leakage and the above priming
undertaken again and checked for water ghtness before connecng to the power socket.
ConsultyourlocalHouseofRohlshowroomforadditionalinformationandspecications.Forcompletewarrantydetailsandalistofshowrooms,gotohouseofrohl.com
houseofrohl.com