Specification Sheet

INSTALLATION INSTRUCTIONS
PROBLEM POSSIBLE CAUSE WHAT TO DO
Water and Steam is sping
from the instant hot water
Dispenser spout
Unit is boiling Turn instant hot water Dis-
penser handle on and release at
least 1 pint of water.
Adjust the water temperature
on the display to a lower
seng.
Check aerator is not blocked
Bleed system to remove any air
Re-Prime bladder to allow cor-
rect operaon.
Water is not hot. The electronic instant hot
water appliance is un-
plugged.
The electronic display has
not been powered up
Make sure the electronic instant
hot water appliance is plugged
in and connected to a grounded
electric outlet
Make sure that the circuit
breaker and fuse are working
correctly
Turn on the power and touch
the on / o buon and then set
the required temperature and
conrm the heat up.
Water is too hot. Water temperature
seng on display panel is
set to high.
Re-set the temperature to the
required temperature and con-
rm the heang up
Water is dripping from the
instant hot water Dispenser
spout.
The expansion chamber
isn't draining the system
correctly due to very
small draw o of water
The spout is blocked
Draw o 1 pint of water to clear
and prime the system. Avoid less
than 1/3 of a pint draw os of wa-
ter. Remove and clean the aerator.
Check silicon pipe length.
TROUBLE SHOOTING
ConsultyourlocalHouseofRohlshowroomforadditionalinformationandspecications.Forcompletewarrantydetailsandalistofshowrooms,gotohouseofrohl.com