01-V/F command group
01- 00
Volts/Hz Patterns (V/F)
Range
1~7
Set 01-00 to one of the following preset V/f selections 1~6according to the required
application.
Parameters 01-02~01-09 are not applicable.
Six fixed V/f patterns are shown below.1~3for 50 Hz systems and 4~6for 60 Hz.
TYPE 50Hz 60Hz
Function
01-00 V/F pattern 01-00 V/F pattern
General Use
=1
100
B
C
12.5 50
(V)%
Hz650
=4
100
B
C
13.0 50
(V)%
Hz650
High start torque
=2
100
B
C
12.5 50
(V)%
Hz650
=5
100
B
C
13.0 50
(V)%
Hz650
Decreasing torque
=3
100
B
C
125 50
(V)%
Hz650
=6
100
B
C
13050
(V)%
Hz650
(V) 100% is the maximum output voltage. B, C point preset % settings will be as table below:-
01- 00 B(Xb) C(Xc)
1/4
10% 8%
2/5
15% 10.5%
3/6
25% 7.7%
Setting 01-00 =[7] provides a flexible V/F curve which can be selected by experienced users by