User manual
4-29
2-wire method. Mode 2.
Example: RUN/STOP and REV/FWD from two inputs ( S1&S2)
Set 00- 04=【1】; S1: 03- 00=【0】(RUN/STOP); S2:03- 01=【1】(REV/FWD);
S1
S2
COM
( RUN /STOP)
( REV/FWD)
S1 ON OFF
FWD
REV
S2
T
Hz
ON
OFF
3-w
ire method.
Example:- Two separate push buttons for RUN & STOP and a two position switch for
FWD/ REV
Set 00- 04 =2.( 3 wire control mode), then terminals S1, S2 and S3 are dedicated to this function and
Preset selections for parameters 03-00, 03-01 and 03-02.are not relevant.
S1(RUN)
S2(STOP)
S3(FWD/REV)
COM
S1
OFF
FWD
REV
S2
S3
ON
ON
ON
Hz
T
OFF
ON