Operation Manual

The
E’ectric
Motor
1.
Line
Voltage
The
motor
works
on
115
volts.
2.
Tensioning
the
Drive
Belt
a)
Loosen
both
screws
holding
the
guard
to
motor
and
remove
the
guard.
Fig.
20
shows
Motor
Housing
with
Guard
removed.
b)
Loosen
the two
screws
b
which
are
now
visible
see
Fig.
20.
c)
By
moving
the
motor
up
or
down,
the
correct
belt
tension
may
be
obtained.
Retighten
both
screws.
3.
Changing
the
Carbon
Brushes
a)
Remove
the
Vbelt.
b)
Take
out
the
4
screws
c
in
motor
end
shield
plate
see
Fig.
20.
The
motor,
complete
with
plate,
can
now
be
drawn
from
the
motor
housing,
to
give
free
access
to
the
carbon
brushes
see
Fig.
20.
24
c
Fig.
20
End
shield
plate
with
screws
for
regulating
the
belt
tension
and
with
fixing
screws
for
access
to
carbon
brushes
25