Operation Manual

Machine
care
Removing
needle:
Unplug
the
machine.
Turn
the
hand
wheel
counter-clockwise
to
raise
the
needle
bar
to
its
highest
position.
Loosen
the
needle
clamp
screw
with
the
allen
wrench
and
pull
the
needle
out.
Inserting
needle:
When
the
needle
bar
is
at the
highest
position,
insert
a
new
needle
in
the
needle
holder,
making
sure
that
the
groove
of
the
needle
faces
you.
Push
the
needle
up
as
far
as
it
will
go
and
tighten
the
needle
clamp
screw.
Notes:
Use
only
System
JL
x
1
(black)
needles
for
the
left
needle
and System
DB
x
1
or 1738,
for
the
right
needle.
Although
the correct
needle
size
depends
on
the
fabric
and
thread
used,
a
size
14
needle
is
recommended.
An
incorrectly
inserted
needle
will
cause
thread
breakage
and
skipped
stitches.
Important:
Left
needle
=
JL
needle;
Right
needle
=
DB
needle
(JL
needle
is
black).
Changing
knives
Knives
are
available
as
spare
parts
and
should
be
replaced
when
they
are
blunt.
Removing
lower
knife:
Unplug
the
machine.
Raise
the
needle
bar.
Push
the
upper
knife
holder
to
the
far
right
and
turn
the
knob
clockwise
until
it
clicks.
23