User's Manual

31
Care and maintenance
10.04 Parameter settings
Parameter settings are described in the separate operations manual for
the drive, and may only be changed by qualifi ed technicians!
See Chapter 3 Specifi cations
*
Adjustment see Chapter 8.05 Basic position of the machine drive unit.
10.04.01 Parameter list for PicoDrive with control unit P41 PD2
Group
Parameter
Description
User lever
Setting range
Set value
1
105 Speed for start backtackl B, C 300 - 2000 1500
110 Speed for end backtack B, C 300 - 2000 1500
6
606 Speed min B, C 30 - 300 180
607 Speed max. B, C 300 - 6000
609 Cutting speed 1 B, C 60 - 300 220
668 Thread wiper/thread blower
1 = on; 0 = off
B, C 0 - 1 0
7
700 Needle position 0
(needle reference position
B, C 0 -255 *
702 Needle position 1 (needle lowered) B, C 0 - 255 79
703 Needle position 2 (take-up lever raised) B, C 0 - 255 222
705 Needle position 5 (end cutting signal 1) B, C 0 - 255 175
706 Needle position 5 (start cutting signal 2) B, C 0 - 255 135
707 Needle position 9 (start thread tension
release/start thread catcher)
B, C 0 - 255 190
797 Hardwaretest (OFF / ON ), B, C OFF
799 Selected machine class C 1 - 3 1
8
800 Rotating direction of the motor C 0 - 1 1
802 Main drive reduction ratio
0 = 1:1, 1 = variable
C 0 - 1 0
9
985 Switch on angle for thread trapper B, C 0 -255 67
986 Switch off angle for thread trapper B, C 0 -255 206
989 Thread trapper at beginning of seam
0 = no
1 = yes
2 = Thread clamp with sewing foot lift
B, C 0 - 2 0