Datasheet

124
Radiant Heater and Fan Heater
FLH 010 - FLH 400
Heat generated by electrical equipment operating under load will prevent the
accumulation of condensation. After the equipment has been switched off
however it cools down and gradually adapts to the ambient temperature, thus
dropping below the dew point.
This is the signal that triggers the heater! These sources of heat prevent the
formation of condensation by raising the internal temperature a few degrees
above the ambient temperature.
In the interest of evenly distributing the heat, we recommend that the require-
ment of heating capacity is divided among several small heaters.
115 V 230 V
(FLH 010-150)
suitable for both
50 Hz and 60 Hz
System of
protection
IP 44
230 V
115 V
We reserve the right to technical alterations.Subject to correction. 075000053
Mechanical data
Fitting position any, vertical position preferred airflow vertical, exit at top
Construction aluminium section, anodised (light-coloured)
Weight 250 g 250 g 250 g 250 g 450 g 510 g 510 g 770 g 1.035 g 1.200 g
Dimensions AAAABBBC D E
Protection class I I
Connection cable end or plug-in terminal plug-in terminal
Binding post clambing area single filament: 2 x 0,5 - 2,5 mm
2
, fine multi-filament: (soldered, wire and sleeve, pin terminal) 2 x 0,5 - 1,5 mm
2
Mounting method snap fastening for 35mm profile bars according to EN 60715
1
)
other voltages (24 V DC, 48V DC) on request
2
)
selected models available in 400V
Thermal data Radiant Heater Fan Heater
FLH 010 FLH 015 FLH 030 FLH 045 FLH 060 FLH 075 FLH100 FLH 150 FLH 250 FLH 400
Heater power (T
u
= + 20 °C) 10 Watt 15 Watt 30 Watt 45 Watt 60 Watt 75 Watt 100 Watt 150 Watt 250 Watt 400 Watt
Max. surface temperature approx. 55 °C 65 °C 90 °C 105 °C 105 °C 120 °C 130 °C 150 °C 70 °C 85 °C
Airflow 50 m
3
/h (50 Hz) 61 m
3
/h (60 Hz)
Duty cycle 100 %
Heating element PTC (positive temperature coefficient), temperature regulating resistance type with temperature monitor
Electrical data
Rated voltage
1
) 230 V (50 / 60 Hz)
2
) 115 V or 230 V
Voltage range 110 - 250 V 104 - 126 V or 207 - 258 V
Power consumption 10 Watt 15 Watt 30 Watt 45 Watt 60 Watt 75 Watt 100 Watt 150 Watt 260 Watt 410 Watt
Starting current approx. 1,0A 1,1A 1,2A 1,8A 2,5A 4,5A 5,0A 7,5A 2,2A / 1,1A 3,6A / 1,8A
Operating temperature - 40 °C (- 40 °F) ... + 70 °C (+ 158 °F) - 20 °C (- 4 °F) ... + 70 °C (+ 158 °F)
Storage temperature - 40 °C (- 40 °F) ... + 70 °C (+ 158 °F) - 40 °C (- 40 °F) ... + 70 °C (+ 158 °F)
System of protection IP 44 (cable end), IP 20 (plug-in terminal), when installed as recommended IP 20, when installed as recommended
Accessories thermostats, hygrostats
Approvals UL approval
Optional extra 2nd protective guard
Supplementary data

Summary of content (2 pages)