Melting/Freezing Point: Not Applicable Flash Point: Non-Combustible
Flammable Limits: LEL: Not Applicable UEL: Not Applicable
Autoignition Temperature: Not Applicable Decomposition Temperature: Not Available
Viscosity: Not Applicable Explosive Properties: Not Explosive
Oxidizing Properties: Not an Oxidizer Relative Density: Not Determined
Molecular Formula: Mixture Flammability (solid, gas): Not flammable
Molecular Weight: Mixture
10. STABILITY AND REACTIVITY
Reactivity: Not reactive
Chemical Stability: Stable
Possibility of Hazardous Reactions: Not expected to occur
Conditions to Avoid: None known.
Incompatible Materials: None known
Hazardous Decomposition Products: Dust from cutting and grinding could contain ingredients listed in Section
3 and other, potentially more hazardous components of the base material being sanded or coatings applied to the
base material.
11. TOXICOLOGICAL INFORMATION
Information on Toxicological Effects:
Ingestion: None expected under normal use conditions. May be harmful if swallowed.
Inhalation: Dust may cause respiratory irritation. May be harmful by inhalation. Prolonged inhalation may cause
lung damage.
Eye: Dust may cause eye irritation. Dust particles may cause abrasive injury to the eyes.
Skin: None expected under normal use conditions. Rubbing product across the skin may cause mechanical
irritation or abrasions.
Acute Toxicity Values:
Aluminum oxide: Oral rat LD50 >15,900 mg/kg; Inhalation rat LC50 7.6 mg/L
Silicon carbide: Oral rat LD50 >2000 mg/kg; Dermal rabbit LD50 >2000 mg/kg
Zirconium dioxide: Oral rat LD50 >5000 mg/kg; Inhalation rat LC50 >4.3 mg/L/4 hr (highest conc. Achievable
with no deaths)
Calcium carbonate: Oral rat LD50 >2000 mg/kg; Inhalation rat LC50 >3 mg/L/4 hr; Dermal rabbit LD50
>2000 mg/kg
Cryolite: LD50 Oral rat >5g/kg, LC50 Inhalation rat 4.45 mg/L/4 hr
Potassium Aluminum Fluoride: LC50 Inhalation rat >4.92 mg/L/1 hr
Manganese Dichloride: LD50 Oral rat 1484 mg/kg
Mixture Calculated Data: LD50 Oral >21200 mg/kg, LC50 Inhalation >7.45 mg/L
Skin corrosion/irritation: Not corrosive or irritating
Eye damage/irritation: May cause eye irritation.
Respiratory irritation: Causes respiratory tract irritation.
Respiratory Sensitization: Not expected to be sensitizing
Skin Sensitization: This material is not known to cause sensitization.
Germ Cell Mutagenicity: Not expected to be a mutagen
Carcinogenicity: None of the components of this product are listed as a carcinogen or potential carcinogen by
OSHA, NTP or IARC.