Installation Guide

13 15
14
13 FLUSHING
For Tub and Shower Combinations
Turn on water supply lines by rotating Stem (13A) counterclockwise allowing
water to ow from tub spout outlet (13B) until all foreign matter has cleared the
line. Water should not be owing from shower outlet (13C) during this test. If
water is owing from shower outlet, please check your valve to see that the
casting mark “SHWR” is facing up (see step 4).
14 FLUSHING
For shower Only Installation
Be sure to plug Bottom Outlet with Pipe Cap or Plug (14A) using Thread Sealant.
Rotate stem (14B) counterclockwise, allowing water to ow from shower outlet
(14C) until all foreign matter has cleared the line.
If water ow becomes low or no ow at all, (refer to Step 20).
15 TEMPERATURE ADJUSTMENT
Adjustment Gear (15A) is factory-set to prevent stem from reaching full hot
position. To adjust stem rotation: Remove Adjustment Gear (15A). Rotate
Stem (15B) counterclockwise to determine a maximum desired temperature.
Replace Gear (15A) aligning Adjustment Stop (15C) to stem Tab Surface (15D)
so Stem (15B) cannot move beyond adjusted point.
5
ENGLISH
ENGLISH
LIMITED TRAVELFULL TRAVEL
13A
13B
13C
14B
14A
14C
15A
15B
15B
15B
15A
15C
15D
15A
15B
15D
15A
15B
15C