Turn off water and relieve pressure by pressing side
sprayer trigger for at least 3 seconds
14 HANDLE REMOVAL
Turn off water before proceeding! With Valves in “Closed” position, unscrew Fastener
(14A) using a Hex Wrench (14B) and remove Handle Hub (14C) from Valve Stem (14D).
15 VALVE CARTRIDGE REMOVAL
Remove handles (See Step 14), unscrew Retainer Nut (15A) by turning it counter-
clockwise and lift out Cartridge Assembly (15B) and inspect. Replace parts as
necessary. Reassemble parts by reversing steps.
18 TEST FOR LEAKS
Turn Handles (18A) to CLOSED position. REINSTALL SIDE SPRAY. Turn water back
ON. Turn Handles to OPEN position and check for leaks. Test Faucet and Side Spray
functions.
A B
16
16C
16B
16A
16 DIVERTER REMOVAL
To remedy low or dual flow, clean or replace diverter. Remove Side Sprayer
Beforehand. Unthread Spout and Diverter Adapter (16A). Assemble Tools as
shown(16B)-TOOLS ONLY INCLUDED AS SPARE 951-084-and push Diverter (16C) out.
17
CAUTION: Maintenance
DISASSEMBLY
1. Replacement parts may be available at the store where you purchased
your faucet.
2. When replacement parts are not available, please write or call Pster
Consumer Service.
3. Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative nishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.psterfaucets.com
• Installation Support
• Care and Warranty Information
Reinstall Diverter
Correctly
17A
17 WASH OUT DEBRIS
Wash out any debris from the Diverter (17A). Afterwards push Diverter back in place
and turn clockwise until stop is reached (approx. 4 turns). Reinstall Spout Hub by
turning clockwise.