User's Manual

050505-36 36ARB2 5
INSTALLATION REQUIREMENTS
The Town & Country Fireplace installation and venting
must conform to the current CAN/CGA-B149 installation
code (in Canada) or the current National Fuel Gas Code,
ANSI Z223.1 (in the USA), and approved per local codes.
Only quali ed (licensed or trained) personnel should
install this product.
In the state of Massachusetts, only a licensed Plumber
and Gas Fitter may install this product.
Fig. # 4
TOP
STANDOFFS
Fig. # 5
Examples of Common Locations
TOP STANDOFFS
The top standoffs are shipped loose inside the  replace and
must be installed on top of the  replace as shown in  g. #4.
Do this once the  replace is on site and in position.
LOCATING THE FIREPLACE
In planning the installation for the  replace, it is necessary to
determine where the unit is to be installed, location of vent
system and where gas supply piping may be plumbed. Vari-
ous installations are possible, such as, into an existing wall,
a corner, a built-in wall or a wall projection (see Fig. #5). Due
to high temperatures, do not locate this  replace in areas of
high traf c or near furniture or draperies.
The minimum clearances from the  replace to combus-
tible surfaces must be adhered to and are shown on Fig.
# 2 and 3.
CAUTION: When selecting a location, ensure
that there is adequate room on the right hand
or left hand side of the  replace for the control
box.
SEE FIG #9 FOR
DIMENSIONS