Wind/Solar Hybrid Controller User Manual Model: HY-C10-24AWM and HY-C10-48AWM Phaesun GmbH · Brühlweg 9 · 87700 Memmingen · Germany · Telefon +49 (8331) 990 42-12 · info@phaesun.com · www.phaesun.
1KW Wind/Solar Hybrid Controller User Manual Notices 1) Battery reversereverse-connection is forbidden. 2) Battery virtual connection or damage is one main factor of malfunction. Please check battery voltage and connection status weekly, clear rust on positive, negative terminal in time; use lead terminal if available. 3) If the malfunction is not easy to eliminate or reason unclear, please write down the phenomenon in detailed record, and contact manufacturer for help in time.
controller will adopt PWM voltage limiting charge mode. It dumps the excess energy. When wind turbine charging current exceeds pre-set brake current point, the controller will automatically start brake to protect battery banks. LCD Display Function: LCD screen can display system status and parameters via visual digital and graphic form. Such as: battery voltage, wind turbine voltage, PV voltage, wind turbine current, PV current, wind turbine power, PV power, battery power status etc.
3. LCD Display Instruction and Key Specification 4.1 LCD Display Instruction 1) Wind turbine symbol. 2) Day symbol. Night symbol. Battery symbol,inner strip graph indicates the battery power status. Five inner horizontal strips display indicates the 3) battery is full. The symbol voltage recover. The symbol voltage recover.
button. 4.
manufacturer in time. Phenomenon Troubleshooting Battery is over-voltage, check battery voltage, and whether the cables are The symbol flashing, without charge well-connected or not, re-connect all components. or discharge a) Firstly, open the software “parameter”-“control”, please check if the setting is “BRAKE”. If yes, please cancel it. LCD display “BRAKE” all the time 6. b) Secondly, Disconnect wind turbine, battery with controller successively.