15.6 Hasselblad 501 CM and 503 CW without Winder
The Phase One IQ back can also be used with mechanical Hasselblad cameras
such as the 501 CM and 503 CW. These cameras are operated in single shot
mode via the shutter release button or a standard cable release.
WARNING! Please note that the Phase One IQ back should not be mounted
while the camera is set to mirror up. Also ensure that the lens is not jammed
or locked open on the “B” setting when connecting the ash sync cable to
the Phase One IQ back.
Shutter Latency Setting
Set the latency setting to Normal on the IQ back while using a mechanical
Hasselblad. Set the latency setting to Zero whilst using the Mirror Up func-
tion or if you need to rapidly press the shutter button. Precautions must be
taken not to trigger the shutter too fast when using Normal latency. If any
problems arise, it is recommended that users look at the green LED on the
back while slowly pressing the mechanical trigger on the camera body. Us-
ers can safely press the button all the way in the moment the LED ashes.
15.7 Hasselblad 503 CW with Winder CW
WARNING! Please note that the Phase One IQ back should not be mounted
while the camera is set to mirror up. Make sure that the lens is not jammed
or locked open on the “B” setting when connecting the ash sync cable to
the Phase One IQ back.
Set the Shutter Latency to Zero when using a 503 CW winder with an IQ back.