User's Manual

Adding to Z-Wave
TM
Network
In the front casing, there is an on/off button with LED indicator below which is used to
carry out inclusion, exclusion, reset or association. After being excluded, its LED
flashes on and off alternately and repeatedly at 2-second intervals. It implies that it
has not been assigned a node ID and cannot work with Z-Wave enabled devices.
Auto Inclusion
The function of auto inclusion will be executed as long as the meter does not
have Node ID and just connect the meter to main power. When first power is applied,
its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It
implies that it is in leaning mode now.
Note: Auto inclusion timeout is 2 minute during which the node information of explore
frame will be emitted once every 5 seconds. Unlike “inclusion” function as shown in
the table below, the execution of auto inclusion is free from pressing the On/Off
button on the meter.
The table below lists an operation summary of basic Z-Wave functions. Please refer
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
Setup function, and to include/exclude/associate devices
Function Description LED Indication
No node ID The Z-Wave Controller does not allocate 2-second on, 2-second off
a node ID to the meter.
Inclusion 1. Have Z-Wave Controller entered
inclusion mode.
One press one flash
2. Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
inclusion mode.
Exclusion 1. Have Z-Wave Controller entered
exclusion mode.
One press one flash
2. Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
exclusion mode.
Node ID has been excluded. 2-second on, 2-second off
Reset 1. Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
inclusion mode.
One press one flash
2. Within 1 second, press and hold
INCLUDE_BUTTON button again
for 5 seconds until LED is off.
3. IDs are excluded.
Association
1.
Have Z-Wave Controller entered
association mode.
Or Pressing INCLUDE_BUTTON three
times within 2 seconds will enter
association mode
One press one flash
2. There are 3 groups for the meter