User's Manual

COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address+Destination End Point = 0x01)
Command Class = 0x32 (Command_Class_Meter_V3 = 0x32)
Command =0x04 (Meter_Supported_Report = 0x04)
Parameter 1 = 0x81 (Meter Reset =1
Meter Type=0x01)
Parameter 2 = 0x75 (Scale Supported =
KWh+W+V+A+Power Factor = 0x75)
2-3-4 METER_RESET
This command is to reset the Accumulated Power Consumption (KWh) to 0
The example show how to reset the KWh
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03 (this is the endpoint of command owner,
here we assume endpoint is 3
if the
owner doesn’t support multi Channel this
value will be 0)
(Bit Address+Destination End Point = 0x01) (Bit Address =0
Destination End Point
range1~3)
Command Class = 0x32 ( Command_Class_Meter_V3 = 0x32)
Command =0x05 ( Meter_Reset = 0x05)
2-3-5 METER_GET
Using meter get command to get the KWH,W,V,I,PF from endpoint of PAB01
2-3-5-1 Get KWH from endpoint
Meter_GET example:
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x05 (this is the endpoint of command owner,
here we assume endpoint is 5
if the
owner doesn’t support multi Channel this
value will be 0)
(Bit Address+Destination End Point = 0x03) (Bit Address =0
Destination End Point
range1~3)
Command Class = 0x32 ( Command_Class_Meter_V3 = 0x32)
Command =0x01 (Meter_Get = 0x01)
Parameter 1 = 0x00 (Scale = KWH = 0x00)
Accumulated power consumption (KWH) Report example
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03 (Meter report = Endpoint3)