User's Manual

Exclusion 1. Put your Z-Wave controller into
exclusion mode by following the
instructions provided by the
controller manufacturer.
One press one flash LED
2. Pressing Include button of PAD02
three times within 2 seconds will enter
exclusion mode.
3. Node ID has been excluded. 0.5s On, 0.5s Off (Enter
auto inclusion)
Reset 1. Pressing Include button of PAD02
three times within 2 seconds will
enter inclusion mode.
Use this procedure only in
the event that the primary
controller is lost or
otherwise inoperable.
2. Within 1 second, press Include button
of PAD02 again for 5 seconds.
3. IDs are excluded. 0.5s On, 0.5s Off (Enter
auto inclusion)
Association 1. The PAD02 is an always listening
Z-Wave device, so associations
may be added or removed by a con-
troller at any time.
Or If your controller requires to have
the PAD02 send a 'node information
frame' or NIF for associations, then
pressing the On/Off button three
times within 2 seconds will cause
the PAD02 to send its NIF.
2. There are only one group for the
switch
Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node
ID allocated by Z-Wave Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Controller.
LED Indication
To distinguish what mode the switch is in, view from the LED for identification.
State Type LED Indication
Normal Whenever we switch On and off of the PAD02 by On/Off button or
RF command, the LED will lights up when switch on; whereas LED
off when switch off.
No node ID Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second intervals.
By pressing On/Off button, it will stop flashing temporarily.
Learning When PAD02 is in learning mode, LED flashes on and off alternately
and repeatedly at 0.5 second intervals.
Choosing a Suitable Location
1. Do not locate the dimmer facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
2