User's Manual

Troubleshooting
Symptom Cause of Failure Recommendation
The Switch not working
and LED off
4. The Switch is not
plugged into the
electrical outlet properly
5. The Switch break down
1. Check power connections
2. Don’t open up the Switch and send it
for repair.
The Switch LED
illuminating, but cannot
control the ON/OFF
Switch of the load
attached
1.Check if the load
plugged into the Switch
has its own ON/OFF
switch
2. The switch is protected
1. Set the ON/OFF switch of the load
attached to ON
2. Unprotected the switch or follow the
instruction of protection.
The Switch LED
illuminating, but the
Detector cannot control
the Switch
1. Not carry out
association
2. Same frequency
interference
1. Carry out association
2. Wait for a while to re-try
Specification
Operating Voltage 100V~240V / 50Hz~60Hz
Maximum Load (watts) 40W (Incandescent bulbs); ( PAD02-1; PAD02-2)
Maximum Load (watts) 13W (Dimmable LED bulbs); ( PAD02-1; PAD02-2)
Screw lamp holder Type: EU type: E27 to E14; PAD02-1
US type: E26 to E12; PAD02-2
Operating Temperature 0°C ~ 40°C
Frequency Range 868.40MHz & 869.85MHz/ EU (PAD02-1);
908.4MHz & 916.0MHz/ USA (PAD02-2);
RF Maximum Power +5dBm
Transmission Range Minimum 40 m in door 100m outdoor line of sight
Modulation Type FSK (Frequency-Shift Keying)
** Specifications are subject to change and improvement without notice.
FCC ID : RHHPAD02
Warning: Do not use Non-Dimmable LED lamps.
Warning:
1.Plug out to disconnect from power supply; Do not plug in line.
2. Do not exceed the max rating.
3. Do not use Non-Dimmable LED lamps.
4