User Manual

Parameter 3 = 0x09 Voltage = 0x0910 = 232.0V
Parameter 4 = 0x10
2-3-5-4 Get load current I from endpoint
Meter_GET example:
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x05 (this is the endpoint of command owner,
here we assume endpoint is 5
if the
owner doesn’t support multi Channel this
value will be 0)
(Bit Address+Destination End Point =
0x03)
(Bit Address =0
Destination End Point
range1~3)
Command Class = 0x32 ( Command_Class_Meter_V3 = 0x32)
Command =0x01 (Meter_Get = 0x01)
Parameter 1 = 0x28 (Scale = A = 0x05)
PAN04 AC load current (I) example
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03 (Meter report = Endpoint3)
(Bit Address+Destination End Point = 0x05) (Bit Address =0
Destination End Point
= command owner Endpoint value)
Command Class = 0x32 (Command_Class_Meter_V3 = 0x32)
Command =0x02 (Meter_Report = 0x02)
Parameter 1 = 0xA1 (Scale Bit2 = 1
Rate Type = 0x01
Meter Type=0x01)
Parameter 2 = 0x4A (Precision = 2
Scale Bit1Bit0 =
0x01
Size = 2)
Parameter 3 = 0x00 Current = 0x002B = 0.43A
Parameter 4 = 0x2B
2-3-5-5 Get power factor PF from endpoint
Meter_GET example:
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x05 (this is the endpoint of command owner,
here we assume endpoint is 5
if the
owner doesn’t support multi Channel this
value will be 0)
14