User Manual

(Bit Address+Destination End Point =
0x03)
(Bit Address =0
Destination End Point
range1~3)
Command Class = 0x32 ( Command_Class_Meter_V3 = 0x32)
Command =0x01 (Meter_Get = 0x01)
Parameter 1 = 0x30 (Scale = PF = 0x06)
PAN04 power factor report example
COMMAND_CLASS_MULTI_CHANNEL
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03 (Meter report = Endpoint3)
(Bit Address+Destination End Point =
0x05)
(Bit Address =0
Destination End Point =
command owner Endpoint value)
Command Class = 0x32 (Command_Class_Meter_V3 = 0x32)
Command =0x02 (Meter_Report = 0x02)
Parameter 1 = 0xA1 (Scale Bit2 = 1
Rate Type = 0x01
Meter Type=0x01)
Parameter 2 = 0x51 (Precision = 2
Scale Bit1Bit0 =
0x10
Size = 1)
Parameter 3 = 0x63 Power Factor = 0x63 = 0.99
3. Z-Wave’s Configuration
Configuration
Parameter
Function Size
(Byte)
Value Unit Default Description
1 Watt
Meter
Report
Period
2 0x01-
0x7FFF
5s 720 5*720s=3600s=1
hour
2 KWH
Meter
Report
Period
2 0x01-
0x7FFF
10min 6 6*10min= 1 hour
3 Slected
End Point
1 1-3 1 1
Relay1 &
Relay2
2
Relay1
3
Relay2
4 Edge or
Pulse
mode or
Edge-
Toggle
1 1-3 1
1Edge mode
2Pulse mode
3Edge-Toggle
mode
15