User Manual

mode
5 Threshold
of Watt
for Load
Caution
2 10-1500
1watt
1500
6 Threshold
of KWH
for Load
Caution
2 1-10000 1KWh 10000
3-1 Watt Meter Report Period:
If the setting is configured for 1hour (set value =720), the PAN04 will report its
instant power consumption every 1 hour to the node of correspond Group. The
maximum interval to report its instant power consumption is 45 hours
(5s*32767/3600=45hr).
3-2 KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), the PAN04 will report its
Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond
Group. The maximum interval to report its Accumulated Power Consumption
(KW/h) is 227.55 days (10min*32767/1440=227.55 days).
3-3 Selected Endpoint
If Controller not using Multi_Channel command class to access the endpoint of
PAN04, you may configure the endpoint value to react the Basic Command Class
Binary Switch Command Class or Meter Command Class V3
3-3-1 Selected Endpoint 1
Default Selected Endpoint is 1
Set command Relay state
Basic Set or Binary_Switch_Set ON Relay1 ON &
Relay2 ON
Basic Set or Binary_Switch_Set OFF Relay1 OFF &
Relay2 OFF
Get command Relay state Report to command sender
Basic_Get or Binary_Switch_Get Relay1 ON or
Relay2 ON
ON
Basic_Get or Binary_Switch_Get Relay1 OFF &
Relay2 OFF
OFF
Get command parameter Report to command sender
Meter_Get KWh Relay1 KWh1+Relay2 KWh2
Meter_Get
Watt
Relay1 W1+Relay2 W2
Meter_Get
Voltage
Relay1 and Relay2 same voltage
16