User Manual
Troubleshooting
Symptom Cause of Failure Recommendation
The Switch not working and
LED off
1. The Switch is not 
connect to the Main 
power
2. The Switch break 
down
1. Check power connections
2. Don’t open up the Switch and 
send it for repair.
The Switch LED 
illuminating, but cannot 
control the ON/OFF
Switch of the load attached
Check if the load connect 
into the Switch has its 
own ON/OFF switch
Set the ON/OFF switch of the load 
attached to ON
The Switch LED 
illuminating, but the 
Detector cannot control
the Switch
1. Not carry out 
association
2. Same frequency 
interference
1. Carry out association
2. Wait for a while to re-try
LED keep flashing 30 
seconds, but cannot control
Overload occurs Remove the load attached or check 
max. load cannot exceed 
1500W~1650W
Specification
Operating Voltage
100 ~240VAC
24-60V DC ±10% (working in this voltage range will have no meter function)
Maximum Load
1500W X2 (220V) 800W X 2 (120V) 
Range Minimum 30 m in door 100m outdoor line of sight
Operating Temperature 0°C ~ 40°C
Frequency Range PAN04-1 868.42 (EU) / PAN04-2 908.42(USA/Canada) / PAN04-3 
922.5/923.9/926.3MHz (Taiwan/JP)MHz
** Specifications are subject to change and improvement without notice. 
 FCC ID : RHHPAN04 
Warning:
1.Plug out to disconnect from power supply; Do not plug in line.
2. Do not exceed the max rating 
Disposal 
This marking indicates that this product should not be disposed with 
other household wastes throughout the EU. To prevent possible harm to
the environment or human health from uncontrolled waste disposal, 
recycle it responsibly to promote the sustainable reuse of material 
resources. To return your used device, please use the return and 
collection systems or contact the retailer where the product was 
purchased. They can take this product for environmental safe recycling.
Company of License Holder
:
Philio Technology Corporation
Address of License Holder
:
8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New 
18