User Manual

the Switch turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to
the Switch turns off.
[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]:
the load attached to the Switch turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the
load attached to the Switch turns off.
2. Z-Wave’s Groups (Association Command Class Version 1)
The Switch can be set to send reports to control associated Z-Wave devices. It
supports 3 association groups which every group has one node support.
Group1~Group3 support SWITCH_BINARY_REPORT,
METER_REPORT_COMMAND_V3
For group 1, the Switch will report (1) ON/OFF status of Relay1 and Relay2 (2)
Instant Power Consumption (Watt) of Relay1 and Relay2 (3) Accumulated Power
Consumption (KWh) of Relay1 and Relay2 to Z-Wave Controller.
For group 2, the Switch will report (1) ON/OFF status of Relay1 (2) Instant Power
Consumption (Watt) of Relay1 (3) Accumulated Power Consumption (KWh) of Relay1
to Z-Wave Controller.
For group 3, the Switch will report (1) ON/OFF status of Relay2 (2) Instant Power
Consumption (Watt) of Relay2 (3) Accumulated Power Consumption (KWh) of Relay2
to Z-Wave Controller.
2-1 Auto report to Grouping 1 ~3(Maximum Node 1)
2-1-1 On/Off Event Report
When “on” or “off state has been changed by pressing S1 S2 or on/off button, it
will send Binary Switch Report to the nodes of Group1~3. But if “on” or “off ” state
has been changed by RF command (ex. Switch Binary set
All Switch ON/OFF or
Basic Set), it will not send.
Binary Switch Report
ON:[Command Class Switch Binary, Switch Binary Report, Value
=(255)0xFF]
OFF:[Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
2-1-2 Instant Power Consumption vary over 5% report
When the power consumption of load vary over 5%, it will send Meter report to the
nodes of Group
5
Meter Report Command: [Command Class MeterMeter
Reportscale(bit 2) +Rate Type +Meter TypePrecision + Scale(bit
1,0)+ SizeMeter Value 1Meter Value 2Meter Value 3
Meter Value
4]