User Manual

Report OFF when both relay 1 and relay 2 OFF
Configuration parameter 1=2 Report ON when relay 1 ON
Report OFF when relay 1 OFF
Configuration parameter 1=3 Report ON when relay 2 ON
Report OFF when relay 2 OFF
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command:
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]
Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF]
Binary Switch Get Command:[Command Class Switch Binary, Switch
Binary Get]
Binary Switch Report Command:
Report OFF:[Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
Report ON:[Command Class Switch Binary, Switch Binary Report, Value =
(255)0xFF]
1-2 BASIC_SET / SWITCH_BINARY_SET
Since the switch have two relay, the load attached to the Switch will turn on or
off upon receipt of the following commands from a Z-Wave Controller by setting
Configuration parameter 1.
Configuration parameter 1=1(default) switch ON and OFF both relay 1 and
relay 2
Configuration parameter 1=2 switch ON and OFF of relay 1
Configuration parameter 1=3 switch ON and OFF of relay 2
,
[Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached to
the Switch turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to
the Switch turns off.
[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]:
the load attached to the Switch turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the
load attached to the Switch turns off.
2. Z-Wave’s Groups (Association Command Class Version 1)
The Switch can be set to send reports to control associated Z-Wave devices. It
supports 3 association groups which every group has one node support.
Group1~Group3 support SWITCH_BINARY_REPORT.
For group 1, the Switch will report ON/OFF status of Relay1 and Relay2
For group 2, the Switch will report ON/OFF status of Relay1
For group 3, the Switch will report ON/OFF status of Relay2
2-1 Auto report to Grouping 1 ~3(Maximum Node 1)
4