User Manual

Relay2 ON
Basic Set or Binary_Switch_Set OFF Relay1 OFF &
Relay2 OFF
Get command Relay state Report to command sender
Basic_Get or Binary_Switch_Get Relay1 ON or
Relay2 ON
ON
Basic_Get or Binary_Switch_Get Relay1 OFF &
Relay2 OFF
OFF
3-1-2 Selected Endpoint 2
Similar like Selected Endpoint 1 but only relate to Relay1 and ignore Relay2
3-1-3 Selected Endpoint 3
Similar like Selected Endpoint 1 but only relate to Relay2 and ignore Relay1
3-2 Edge / Pulse / Edge-Toggle mode
Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle
mode , default value is Edge mode.
Edge mode: this mode is suitable for the bi stable wall switch that has indicator point
on the switch, and the same position correspond to same state of relay1 and relay2 .
if the PAN06 relay change the state because of receiving Z-Wave RF command, it
may need two times of change (switch on to off or switch off to on) to let relay back
to the correspond state.
Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of
Relay1 or Relay2
Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time
when change the state of the wall switch will also swap the state of Relay1 or Relay2
4. Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_SWITCH_BINARY
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_VERSION
* COMMAND_CLASS_SWITCH_ALL
* COMMAND_CLASS_ASSOCIATION_V1
* COMMAND_CLASS_CONFIGURATION
* COMMAND_CLASS_MULTI_CHANNEL_V3
* COMMAND_CLASS_ALARM
Troubleshooting
Symptom Cause of Failure Recommendation
The Switch not working and
LED off
1. The Switch is not
connect to the Main
power
2. The Switch break
down
1. Check power connections
2. Don’t open up the Switch and
send it for repair.
7