User's Manual

Troubleshooting
Symptom Cause of Failure Recommendation
The Switch not working and
LED off
1. The Switch is not
connect to the Main
power
2. The Switch break
down
1. Check power connections
2. Don’t open up the Switch and send
it for repair.
The Switch LED
illuminating, but cannot
control the ON/OFF
Switch of the load attached
Check if the load connect
into the Switch has its
own ON/OFF switch
Set the ON/OFF switch of the load
attached to ON
The Switch LED
illuminating, but the
Detector cannot control
the Switch
1. Not carry out
association
2. Same frequency
interference
1. Carry out association
2. Wait for a while to re-try
LED keep flashing 30
seconds, but cannot control
Overload occurs Remove the load attached or check
max. load cannot exceed
6A(1260W~1500W / 230V)
Specification
Operating Voltage
90 ~240VAC
24-60V DC ±10% (working in this voltage range will have no meter function)
Maximum Load
5AX2; 1100W X2 (220V); 600W X 2 (120V) ;
Range Minimum 30 m in door 100m outdoor line of sight
Operating Temperature 0°C ~ 40°C
Frequency Range PAN07-1 868.40MHz ,869.85MHz (EU) /
PAN07-2 908.40MHz ,916.00MHz (USA/Canada) /
PAN07-3 922.~927MHz (Taiwan/JP)MHz
** Specifications are subject to change and improvement without notice.
FCC ID : RHHPAN07
Warning:
1.Plug out to disconnect from power supply; Do not plug in line.
2. Do not exceed the max rating
Disposal
This marking indicates that this product should not be disposed with
other household wastes throughout the EU. To prevent possible harm to
the environment or human health from uncontrolled waste disposal,
18