User's Manual
Rate Type = 0x01
Meter Type = 0x01
Precision = 2
Scale = 0x06(PF)
Size = 1 Bytes
Meter Value 1
Example:
Scale = 0x06 (PF)
Precision = 2
Size = 1 (1 Byte of PF)
Meter Value 1 = 0x63(PF)
Load power factor (PF) = Meter Value 1 = 0.99
4-2.6 reset Accumulated Power Consumption (KWh)
This command is to reset the Accumulated Power Consumption (KWh) to 0
Meter Reset Command
:
[Command Class Meter, Meter Reset]
4-3 Alarm Report Command
:
When PAN08 detect Overload
,
it will send Alarm_Report to Group1
,
Alarm
Level=0xFF
。
When receive Alarm_Get command and the PAN08 not in overload sta-
tus , it will send Alarm_Report
,
Alarm Level=0x00
。
4-3.1 Alarm Report
:
[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level = 0xFF
(Overload)]
[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level = 0x00
(Normal)]
5 Z-Wave’s Configuration
Configuration
Parameter
Function Size
(Byte)
Value Unit Default Description
1 Watt
Meter
Report
Period
2 0x01-
0x7FFF
5s 720 5*720s=3600s=1
hour
2 KWH
Meter
2 0x01-
0x7FFF
10min 6 6*10min= 1 hour
10
Meter Report Command:
[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter
Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1]










