User's Manual

Report
Period
3 Threshold
of Watt
for Load
Caution
2 10-1100
1watt
1100
4 Threshold
of KWH
for Load
Caution
2 1-10000 1KWh 10000
5-1 Watt Meter Report Period:
If the setting is configured for 1hour (set value =720), the PAN08 will report its
instant power consumption every 1 hour to the node of correspond Group. The
maximum interval to report its instant power consumption is 45 hours
(5s*32767/3600=45hr). Default value is 1 hour
5-2 KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), the PAN08 will report its
Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond
Group. The maximum interval to report its Accumulated Power Consumption
(KW/h) is 227.55 days (10min*32767/1440=227.55 days). Default value=1 hour
5-3 Threshold of Watt for Load Caution
This is a warning when the wattage of load over the preset threshold value, If the
setting value is 1100, when the load wattage over this value, PAN08 will send Watt
Meter Report command to the node of correspond Group. Default value=1100W
5-4 Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the
setting value is 10000, when the Accumulated Power Consumption of Relay1 or
Relay2 over this value, PAN08 will send KWh Meter Report command to the node of
correspond Guoup, minimum value is 1KWh and default value is 10000 kWh
6. Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_SWITCH_BINARY
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_VERSION
* COMMAND_CLASS_ASSOCIATION
* COMMAND_CLASS_METER_V3
* COMMAND_CLASS_CONFIGURATION
* COMMAND_CLASS_SWITCH_MULTILEVEL_V3
* COMMAND_CLASS_ALARM
Troubleshooting
Symptom Cause of Failure Recommendation
11