Overload When overload state occurs, the PAN08 is disabled of which LED
flashes on and off alternately at 0.5 second intervals. Overload
state can be cleared by disconnect and reconnect the PAN08 to
the main power
Choosing a Suitable Location
1. Do not locate the PAN08 facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the PAN08 is 0°C~40°C.
3. Do not locate the PAN08 where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of PAN08 will become a little bit hot of which
phenomenon is normal.
Installation and operation
1. put the in wall PAN08 into a wall box and connect the AC power wire L,N to
PAN08 connector L, N.
2. Connect the wall switch to the PAN08 as Fig1 .
3. It is important to carry out a shutter calibration process before you control the
shutter to move. Press inclusion button over 3 seconds and release before the
6th second, the roller shutter controller will start the shutter calibration process.
The process is composed of three continue stages. The shutter move to the TOP
in first stage, and move to the BOTTOM in second stage, and move to the TOP
again in third stage. Then PAN08 will know the total range of UP and DOWN.
4. During the shutter calibration process, any emergencies happen you can press
and release the include button to stop the process
5. If user found the direction is reverse, this may because the wrong connection of
NC and NO to the motor, please change NC and NO connection and execute
calibration process again.